Passed SIL2/3 safety certification
Digital signal output (4-20mA, HART, Modbus, wireless LoRa, etc.)
Built-in RFI/EMI filtering module to improve measurement accuracy
Self-compensation and self-diagnosis, multi-point linearization, high precision and high stability
l HART communication, 4-20mA
l Multilingual full text graphics LCD display
l It is easy to adapt to the measurement point without calibration on site
l Smooth filtering algorithm, more stable output signal
l SIL2 security certificate (HART type)
l Continuous self-diagnosis, status and diagnostic information
l Process temperature range -196℃~400℃
l Use corrosion-resistant materials

Passed SIL2/3 safety certification
Digital signal output (4-20mA, HART, Modbus, wireless LoRa, etc.)
Built-in RFI/EMI filtering module to improve measurement accuracy
Self-compensation and self-diagnosis, multi-point linearization, high precision and high stability
l Power supply voltage: 12~30VDC; reverse polarity protection is provided in the indicator (indicator voltage ≥ 17.75VDC during communication with HART protocol)
l Output signal: 4~20mA, two-wire system
l Measuring range: 300mm~3000mm (can be made beyond the range)
l Nominal pressure: ≤PN420 (Class 2500)
l Nominal diameter: DN80, DN100 or according to user requirements
l Ambient temperature:-40℃~+80℃ (When ≤-20℃, the liquid crystal has no display)
l Operating temperature:-70℃~+450℃
l Measurement accuracy: ±0.5%FS
l Power supply influence: When the power supply changes between the minimum and maximum value of the specified voltage, the output changes <±0.2% full scale
l LCD display: output current signal, process variable, process temperature, percentage range, torque tube rotation angle
l Difference in medium density: ≥0.08g/m3
l Torque tube material: standard Inconel600, optional Monel, Hasetlloy-276 liquid contact material: 304, 316L or according to user requirements
l Flange standard:HG/T20592-2009, HG/T20615-2009 or according to user requirements
l Cable port:2 NPT1/2 (internal thread) or according to user requirements
l Explosion-proof type: Intrinsically safe Exia IIC T1~T6 Ga, Explosion-proof Exd IIC T1~T6 Gb
l Protection level: IP66
Oil and gas:
l Accurate measurement of oil-water interface liquid level in crude oil dehydration system
l Continuous monitoring of liquid level and buffer tank level in the fractionation tower of the refinery
l Liquid level monitoring of condensate and amine liquid storage tanks in natural gas treatment plant
l Liquid level management of liquefied natural gas (LNG) storage tanks and high-pressure recovery systems
Chemical Industry:
l Continuous measurement of tank liquid level of corrosive media (such as sulfuric acid, hydrochloric acid, organic solvents)
l Layered measurement of interfaces of fine chemical equipment (oil, water, liquid and liquid)
l Real-time control of high temperature and high pressure liquid level in the polymerization reactor and process intermediate tank
This website uses cookies to ensure you get the best experience on our website.