Very accurate and reliable direct liquid level measurement technology
Not affected by physical parameters such as temperature, pressure, and density
Penetrating foam to measure liquid level, can measure strong acid and strong alkali liquid level
l Very accurate and reliable direct liquid level measurement technology, without the need to target variable process conditions (such as density, conductivity, viscosity degree, pH, temperature and pressure) compensate
l No moving parts and no recalibration is required to minimize maintenance
l Can handle interference from steam, dust, turbulence and foam
l Suitable for small storage tanks, storage tanks with complex geometric shapes, and obstacles in the tank, and not subject to bypass pipe mechanical design affects top installation, thereby minimizing the risk of leakage
l Available in a variety of materials, process connectors, waveguide rod types and accessories
l A variety of options for optimal coordination with existing bypass pipes for an overall solution
l Available in a variety of materials, process connectors, waveguide rod types and accessories
l With echo curve display function, convenient for on-site debugging through four buttons

Very accurate and reliable direct liquid level measurement technology
Not affected by physical parameters such as temperature, pressure, and density
Penetrating foam to measure liquid level, can measure strong acid and strong alkali liquid level
l Maximum range: Cable: 30m rod: 4m
l Accuracy: ±3mm
l Process connection: G1, G1½, 1”NPT, 1½”NPT, DN25-DN200
l Antenna material: 316L+PTFE
l Antenna outer diameter: cable: 6mm rod: 10mm
l Process temperature: -40~150℃
l Process pressure: -0.1~4.0MPa
l Dielectric constant:>1.6εr
l Signal output: 4~20mA/HART
l Power supply: two-wire system (DC24V); four-wire system (DC24V/AC220V)
l Explosion-proof sign:From IA 2 c t1 ~ t6 ga
From 500 is [IA GA] 2 c T1 ~ T6 GB
Oil and gas:
l Accurate measurement of liquid level and oil-water interface between storage tanks such as crude oil, diesel, and light hydrocarbons
l Real-time monitoring of liquid levels of oilfield production liquid separators, buffer tanks and dehydration tanks
l Liquid level and density measurement of storage tanks such as LNG and LPG
l Liquid level monitoring of odorant tanks and high-pressure filling systems in natural gas stations
Chemical Industry:
l Accurate measurement of liquid level and interface in high-temperature and high-pressure reactors and storage tanks
l Storage tank level control of corrosive media (such as sulfuric acid, hydrochloric acid, hydrofluoric acid)
l Stabilization measurement of liquid level of chemical tanks with volatile, foam and stirring
l Continuous monitoring of liquid level of fine chemical and pharmaceutical intermediate storage tanks
The non-contact microwave ranging method uses a 26GHz microwave frequency to emit a beam of microwav...